Managed Gigabit Switch
282 T1000-TM-EN-2
282
VeriPHY
VeriPHY Diagnostics
This page is used for running the VeriPHY Cable Diagnostics for 10/100 and 1G copper ports.
Press to run the diagnostics. This will take approximately seconds. If all ports are selected, this can take
approximately 1 seconds. When completed, the page refreshes automatically, and you can view the
cable diagnostics results in the cable status table. Note that VeriPHY is only accurate for cables of
length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10
or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port:
Port number.
Pair:
The status of the cable pair.
OK - Correctly terminated pair
Open - Open pair